How to read a commercial EPC certificate

Updated 23 October 2026 · SEO Dons Editorial

A commercial EPC on the GOV.UK register reads from top to bottom: a summary panel, the rating, how similar properties compare, a technical breakdown, a link to the recommendation report, and who produced the certificate and when. The specimen below shows that layout, the sections after it explain each part, and a checklist covers a sale or letting. To run the figures from your own certificate through a validity and MEES check, use the commercial EPC checker.

What does a commercial EPC look like?

This specimen follows the sections of a certificate page on the register. Every value is invented to show the layout. It is not a real certificate and does not describe any real building.

Section on the register pageSpecimen entry (all values invented)
Summary panelEnergy rating D; valid until [a date 10 years after lodgement]; certificate number XXXX-XXXX-XXXX-XXXX-XXXX; property type [planning use class]; total floor area 1,250 square metres
Energy rating and score“This property’s energy rating is D” with a score [number]
How this property compares to othersIf newly built [score]; if typical of the existing stock [score]
Breakdown of this property’s energy performanceMain heating fuel: natural gas; building environment: heating and natural ventilation; assessment level: 3; building emission rate [kgCO2/m² per year]; primary energy use [kWh/m² per year]
Recommendation reportA link to the separate report
Who to contact; About this assessmentAssessor’s name, accreditation scheme and ID; employer; assessor’s declaration; date of assessment; date of certificate
Other certificates for this propertyEarlier certificate numbers with their valid-until dates

What does the rating show, and what does it leave out?

The band runs from A+ (best) to G (worst), with a score beside it. The government guide says the energy performance of a non-dwelling is shown as a carbon dioxide based index and that the lower the number, the lower the typical emissions, so on a commercial certificate a lower score is the better one.

The regulations call it an asset rating: an energy performance indicator determined from the amount of energy estimated to meet the different needs associated with a standardised use of a building. GOV.UK’s technical annex says what sits underneath. Despite the “Energy Rating” label, “the underlying metric is a carbon emissions metric”, and the register puts it this way: “The better the rating and score, the lower your property’s carbon emissions are likely to be.”

That has three consequences. The rating is not a forecast of your bills, because it assumes a standard use. It counts only “regulated” energy, which the annex lists as space heating, water heating, space cooling, ventilation and fixed lighting, so cooking and plug-in appliances are left out. And the score is the same whoever occupies the building. How commercial EPC ratings are worked out covers the method.

What do “if newly built” and “if typical of the existing stock” mean?

Under the headline the register shows how similar properties could rate if newly built and if typical of the existing stock. The regulations require a certificate to include a reference value “in order to make it possible to compare and assess the energy performance of the building”. Read the two figures as context: on a scale where lower is better, a score above the typical-stock figure means the building is behind comparable existing buildings. They do not change the legal position, which for a covered letting is still band E.

What is in the technical breakdown?

EntryWhat it recordsWorth checking
Main heating fuelThe fuel the model assumed for the main heatingThat it matches the building: the rating uses emission factors for the fuels used
Building environmentHow the building is conditioned, such as heating with natural ventilation or air conditioningThat the systems shown are the ones installed
Assessment level3, 4 or 5. Levels 3 and 4 can both be assessed with SBEM; level 5 buildings are assessed with dynamic simulationThat the level suits the building: see SBEM Level 3, 4 and DSM
Building emission rateThe carbon dioxide emission rate the model gives the building, shown per square metre per yearThat it is consistent with the rating band shown
Primary energy useThe energy required for lighting, heating and hot water, including the energy used to produce and deliver the fuelThat you do not read it as metered use: it is modelled

A target emission rate is a different idea. It belongs to the Building Regulations compliance check, and the NCM site explains that the target rates come from a notional building of the same size, shape and use. You do not need it to read an existing building’s certificate. The floor area is covered in how floor area is measured on a commercial EPC.

What do the dates, certificate number and assessor details tell you?

The valid-until date reflects the 10-year rule in regulation 9: a certificate is valid if it was entered on the register no more than 10 years before it is made available and no later certificate for the building has been entered since. The register lists other certificates for the property, so check that none is newer. The certificate number is what the regulations call the report reference number, and it is how a certificate is looked up on the register.

The assessor’s details matter if something looks wrong. The register says to complain to the assessor who created the certificate first, and to contact the accreditation scheme if that fails. The declaration records any personal or business relationship the assessor has with the person who commissioned it (regulation 23). How to find a commercial EPC on the register covers searching.

Where does the recommendation report fit?

The certificate points to a separate recommendation report, which must be included unless there is no reasonable potential for energy performance improvements compared with the requirements in force. The government guide says it groups measures by payback: short term under 3 years, medium term 3 to 7 years and long term over 7 years. How to read a commercial EPC recommendation report goes through it.

What should you check before a sale or letting?

  1. Validity. The valid-until date has not passed and no newer certificate is listed.
  2. Rating against band E. For a covered letting, a property is sub-standard where its valid EPC is below band E. Most fixed lettings of six months or less and leases of 99 years or more are outside the rule. The proposal for EPC B from 2031 for privately rented buildings over 1,000 square metres is not law.
  3. Floor area. Compare it with the 500 square metre display threshold and, for the proposal, the 1,000 square metre line.
  4. Extent. The certificate covers the unit being sold or let. A block with a common heating system can use one certificate for the whole building.
  5. Adverts. Once an EPC exists, the rating has to appear in adverts in commercial media. The EPC graph generator draws the A+ to G scale for listings.

Sources

Common questions

Is a higher score better on a commercial EPC?

No. The government guide says the lower the number, the lower the typical emissions. The register runs the bands from A+ (best) to G (worst) and says the better the rating and score, the lower the carbon emissions are likely to be.

Does the certificate show my energy bills?

No. It is an asset rating for a standardised use, and the technical annex says the current EPC metrics evaluate only regulated energy uses, which exclude cooking and plug-in appliances.

Does one certificate cover every unit in a building?

Not always. The regulations allow a non-residential building to be certified as a whole where it has a common heating system, and the government guide says that certificate can be used for any part when it is sold or let. Where units have independent heating, each unit needs its own.