NABERS UK vs EPC: what each office rating tells you
Updated 23 October 2026 · SEO Dons Editorial
What is NABERS UK?
NABERS UK is an energy rating scheme for offices, adapted from the NABERS programme that operates in Australia. Its administrator describes it as a scheme that, "unlike design-based energy ratings", measures and rates the actual energy use of offices. The rating is shown as one to six stars. It sits beside the EPC, not in place of it.
CIBSE Certification runs the scheme day to day. CIBSE was announced as the new administrator on 2 April 2024, taking over from BRE. NABERS UK currently rates offices only. There are two products: Energy for Offices, which rates existing buildings, and Design for Performance, covered below.
Energy for Offices measures an operational office building "based on metered data". The rating compares the building's energy consumption with a set of benchmarks. Those benchmarks come from actual performance data from UK offices, and the rating takes account of location and occupancy. Offices can be rated in three ways:
- Base building. The building's central services, such as heating and cooling systems, lifts and lobby lighting.
- Tenancy. The energy used by the tenant, typically for lighting and power, plus special tenancy requirements or local air conditioning.
- Whole building. The energy used by office tenancies and by base building services to lettable and common spaces.
To get a rating you need a Licensed Assessor to assess the building. A building is eligible if, during the rating period, the building or part of it was used as an office or, if empty, was capable of being used as one. Ratings can be published or kept private.
How do an EPC, NABERS UK and a DEC compare?
| Point | EPC | NABERS UK Energy for Offices | DEC |
|---|---|---|---|
| What it measures | A modelled asset rating: energy estimated for a standardised use of the building | Energy efficiency of an operational office, based on metered data | Actual metered energy over the last 12 months (the operational rating) |
| Scale | A+ to G | One to six stars | A to G |
| Who it is for | Any non-domestic building that is constructed, sold or rented out | Offices, or parts of buildings used as offices | Occupiers of public authority buildings frequently visited by the public |
| Legal status | Required by the 2012 Regulations on construction, sale or letting | A separate scheme, not an EPC or DEC under those Regulations | Required of the occupier by the 2012 Regulations |
| Validity | 10 years, or until a newer EPC is lodged | Rating validity period generally 12 months | 12 months or 10 years, depending on size |
| How it is used | Made available to buyers and tenants; its band is the test for MEES on lettings | Base building, tenancy or whole building ratings; can be kept private | Displayed by the occupier, with an advisory report |
Where an office building has a common heating system, the government's guide says an EPC may be prepared for the whole building and used for any part when sold or rented out. NABERS UK instead splits a building by who controls the energy: the landlord's base building services, the tenant's own use, or both together. The EPC works from the physical building and the NABERS rating works from the meters.
Does NABERS replace an EPC?
No. The duties in the 2012 Regulations attach to energy performance certificates and display energy certificates, and the Regulations require a seller or landlord to make a valid EPC available to a prospective buyer or tenant. Construction adds a duty: when a new building is physically complete, the person carrying out the construction must give the EPC and recommendation report to the owner.
MEES uses the EPC too. Under the 2015 Regulations a property is sub-standard where its valid energy performance certificate expresses its performance as below band E, and a landlord of a sub-standard non-domestic property must not let it unless an exemption applies. A NABERS UK rating is not an EPC, so it does not stand in for the certificate in that test. The guide to how commercial EPC ratings are worked out and the MEES compliance page cover that side.
Why can the two ratings tell different stories?
Because one is built from a model and the other from meter readings. On an EPC, the parameters and schedules for each activity are standardised and cannot be modified by the user, so a tenant's habits do not move the band. A NABERS UK rating is based on metered consumption, and it takes occupancy into account. Even a Level 5 EPC, produced in dynamic simulation software, is still an asset rating calculated to the approved methodology. Can a Level 5 (DSM) EPC change your rating? explains what that method does differently.
The DEC is closer to NABERS in principle, because it is also based on metered use. The DEC guide says typical performance for a building type scores 100. NABERS UK benchmarks are set from UK office data to give a median. The two are separate scales for separate purposes, and none of the sources used for this page converts one into the other. Nothing here says what rating any office will achieve.
As a hypothetical illustration, an office could hold a certificate describing a well-specified building and, separately, a metered rating that reflects how it is operated. They answer different questions. Display Energy Certificates: which buildings need a DEC? explains the third column of the table.
What is Design for Performance, and how does it sit beside a new-build EPC?
Design for Performance (DfP) is "the process whereby a developer or owner commits to design, build and commission a new office development or major refurbishment to achieve a specific NABERS UK Energy rating". The target comes first and the measured result comes later. The scheme says new buildings and major refurbishments are eligible for a rating as soon as 12 months of a rating period can be completed, and that a DfP target rating remains valid until the first actual rating is received.
The EPC on a new office is different: it is due when construction is physically complete and is modelled, not measured. A new office that enters DfP can therefore hold an EPC from completion and, later, a NABERS UK rating based on its first year of metered use. For the EPC side, see how commercial EPC ratings are worked out.
Which should an office owner or occupier look at first?
- The legal minimum. Check whether the office has a valid EPC before a sale, letting or completion, and whether a let office is below band E. The office EPC guide covers the triggers and MEES for offices.
- The occupier's duty. If a public authority occupies the building and the public visit often, check the DEC rules.
- The optional rating. If you want a metered benchmark, ask a NABERS UK Licensed Assessor whether the building and the energy data meet the eligibility criteria, and whether you want the result published or private.
The first step often needs an EPC assessment, and an enquiry can be sent through the site's quote form for an office EPC.
Sources
- About NABERS UK, Energy for Offices and Design for Performance, CIBSE Certification, checked 22 October 2026
- NABERS UK (frequently asked questions), CIBSE Certification, checked 22 October 2026
- NABERS UK and NABERS UK partners with CIBSE as new UK scheme administrator (2 April 2024), CIBSE, checked 22 October 2026
- A guide to Energy Performance Certificates for the construction, sale and let of non-dwellings, Ministry of Housing, Communities and Local Government (GOV.UK), updated 11 December 2017, checked 22 October 2026
- A guide to display energy certificates and advisory reports for public buildings, Ministry of Housing, Communities and Local Government (GOV.UK), updated 10 August 2015, checked 22 October 2026
- Energy Performance Certificates for your business premises, GOV.UK, checked 22 October 2026
- The Energy Performance of Buildings (England and Wales) Regulations 2012, regulations 2, 6, 9 and 14, and the table of contents, legislation.gov.uk, checked 22 October 2026
- The Energy Efficiency (Private Rented Property) (England and Wales) Regulations 2015, regulations 22 and 27, legislation.gov.uk, checked 22 October 2026
- NCM and SBEM frequently asked questions, uk-ncm.org.uk (BRE-run NCM and SBEM website), checked 22 October 2026
- Commercial EPCs, Elmhurst Energy, checked 22 October 2026
Common questions
Who runs NABERS UK now?
CIBSE Certification administers the scheme day to day. CIBSE was announced as the new administrator on 2 April 2024, taking over from BRE. The scheme is based on the NABERS programme that operates in Australia.
Can a brand-new office get a NABERS UK rating at handover?
Not from a standing start. The scheme says new buildings and major refurbishments are eligible once 12 months of a rating period can be completed. The EPC is the certificate due when construction is physically complete.
Can a tenant get a rating for just their floor?
Tenancy ratings exist for that purpose: they rate the energy used by the tenant, typically for lighting and power. Eligibility applies to a building or part of a building used as an office. A Licensed Assessor can confirm whether a particular floor qualifies.
Is a high NABERS UK rating the same as a good EPC?
No. They use different scales and different evidence, a metered rating on one side and a modelled asset rating on the other. None of the official sources used for this page converts one into the other, so check each separately.